Closes Chapter 7's open item — a braced 4×4 leg beats the NDS slenderness cap without upsizing to 6×6, if the bracing is sized right.

Concepts pulled in

  • Method of joints
  • Unbraced length vs. total length

Chapter 7 left an open item: a 16 ft 4×4 leg passes the load-capacity check but fails NDS's slenderness limit (Le/d ≤ 50). Two fixes were on the table — upsize to 6×6, or brace it. This chapter works the bracing option, because it's the one that teaches something instead of just buying more lumber.

The idea: slenderness is about unbraced length, not total length. A 16 ft leg braced at the midpoint doesn't act like a 16 ft column anymore — it acts like two 8 ft columns stacked, because the brace holds the midpoint from moving sideways. Le/d is calculated on the unbraced segment, so cutting the unbraced length in half roughly quarters the buckling risk (Pcr scales with 1/Le²).

Sizing the brace panel: a simple X-brace (or single diagonal, depending on which face needs it) between two legs at mid-height turns each half of the tower into a small truss panel. At the panel point where the diagonal meets the leg, method of joints applies: draw the joint, sum forces in x and y, solve for the diagonal's axial force under the lateral (wind) load the tower has to resist. The diagonal only needs to be sized for that force — it's a tension/compression member, not a bending member, which is why a much smaller piece of lumber (or even strapping, depending on the force) can do the job.

Answer

Bottom line for a 4×4 leg, braced at mid-height: Le drops from 16 ft to 8 ft, Le/d drops from about 55 (over the 50 cap, as Chapter 7 found) to about 27 — comfortably under it, no upsizing needed. Breyer Chapter 5 checks the braced 4×4 and the 6×6 under the NDS column rules: the braced 4×4 carries about 6,170 lb and an unbraced 6×6 about 7,590 lb, against 112 lb per leg. The trade-off is a bracing member and its connections, which have their own fastener check (back to Chapter 8's 4-bolt rule).

Open items for a later pass

The actual lateral wind load on the tower face, and the resulting diagonal force, needs the real tower height/width once it's a confirmed build rather than the 16 ft test-tower placeholder. Once there is a brace force, Breyer Chapter 7 checks the wood a brace bears on at an angle to the grain.